|
|
Scene properties - Electronics |
|
|
scene properties § visual settings § simulation § meters § logic § part IDs |
Scene propertiesThe electronics scene properties are used to set properties relating to any electronic parts in the active scene. Changing the properties of one scene will not change the properties of other scenes in a model, unless stated otherwise.
The electronics scene properties can be accessed as follows:
|
Visual settings
Used to alter the display of current arrows on wires. Choose from
Used to turn the display of logic signals on and off.
Logic signals appear on the terminals of electronic parts. Three possible logic states can be displayed:
Used to turn the display of bar voltmeters on and off.
Bar voltmeters appear on the terminals of electronic parts. The size of the bars indicates the voltage on the terminal, relative to the circuit ground.
The bar voltmeters are made up of smaller blocks, where each block represents 2V. Red-black bars indicate positive voltage and blue-black bars indicate negative voltage. If the voltage is more than 8.5V the bar voltmeter is drawn as a solid red rectangle, and as a solid blue rectangle if the voltage is less than -8.5V.
Used to turn the display of part values on and off.
When the part value display is off, part values can only be accessed via the Properties pane.
Used to turn the display of part controls on and off.
Part controls include any sliders, buttons, switches or handles that appear on parts allowing them to be manually controlled in-scene. For example, the slider on a variable voltage supply.
|
Simulation
Choosing this option makes all electronic parts in the scene indestructible. That is, they are not destroyed when their maximum ratings are exceeded.
Choosing this option sets the internal resistance of all batteries in the scene to 1 ohm. Otherwise batteries have no internal resistance.
This displays the minimum sample rate as set in the scene’s Properties pane (General).
|
Meters
If the autorange option is chosen, ammeters and voltmeters display prefix letters m (milli) or µ (micro) if necessary.
If the measure RMS option is chosen, ammeters and voltmeters display the root-mean-square values of current or voltage.
|
Logic
Choosing this option turns on the display of IEC logic signals.
Choosing this option turns on the display of IEC analog signals.
There are two logic families to choose from: 74HC and 4000. The logic family chosen applies to both logic gates and logic integrated circuit parts.
The 74ACT logic family option is no longer available as it has become obsolete within the electronics industry. Models that used the 74ACT family will be automatically converted to 74HC when loaded in Rabbit Chemistry.
Used to set the supply voltage for the chosen logic family.
Displays the output drive current for the chosen logic family. This property is read-only.
|
Parts IDsEach part has a unique ID. By default, electronics parts are auto-IDed meaning that their IDs cannot be changed in the Properties pane..
|